1 min read

Release Notes: March 2025

QuickQnect / Tekla Specific Enhancements
  • Add NoConnect graph options in No Connections Summary Report
    • image.png
  • Bolts clashing with Shear Plate in column web - In certain instances an erection issue was occurring with a Double Angle on column flange and a shear plate on column web.  This has been resolved.
    • image.png
  • Web-environment: issue with tables: unable to scroll, unable to copy and paste rows - The scroll bar on the mandated preferences pages was not operating properly.  This has been resolved.
    • image.png
  • Clean-up profiles drop down lists sort and values (forces page ONLY) - this was done for HSS as a secondary
  • Issue with CJP welds preps on Moment Connections with CISC building codes has been resolved.
  • End Plate connections have incorrect cost data for bolts.  This has been resolved.
  • HSS tnom vs tdes
    • 1. This preference will be removed from the web pages and therefore should no longer be used by the engineering app.
    • For connections to an HSS support and for HSS filler beams with CSA G40.21 or A1085 material, can Qnect use tnom instead of tdes when checking strength limit states?
      • ()Yes ()No
    • 2. In the new solution, the app is expected to always use “tnom” value and name with A1085 and CSA G40.21 (350W) HSS material grades.
    • 3. This note on sample calculations for A1085 material
    • ”Using tnom per user preferences for A1085 material” should be changed to “Using tnom for A1085 material” and this note for G40.21 (350W) material
    • “Using tnom per user preferences for G40.21 material” changed to “Using tnom for G40.21 (350W) material”
  • Show new fields on Mandated shear plate preferences to meet customer requirements
    • image.png
  • When No Connection overwrites red connection it changes the loads back to the original load.  It has been changed to keep any loads entered in the UDA by the user.
  • Update CISC moment and axial flags = ON in all environments - CISC moment connections and moment connections with axial has been turned on.

Release Notes: February 2025

QuickQnect / Tekla Specific Enhancements

Read More
Release Notes: January 2025 | Qnect

Release Notes: January 2025 | Qnect

QuickQnect / Tekla Specific Enhancements Connection Error - An error arose where a group with 4 Beam to HSS Column all were connected. Then one...

Read More

1 min read

Release Notes: April 2025

QuickQnect / Tekla Specific Enhancements Change colors on NoConnect graph Preference report needs new fields Upgrades to latest version for...

Read More