title: "Release Notes: April 2024 | Qnect"
description: Explore Qnect’s April 2024 release notes featuring powerful upgrades, bug fixes, and workflow improvements. See what’s new and streamline your projects!
---

[News & Product Updates | Qnect ](https://www.qnect.com/news-product-updates)

# [Release Notes: April 2024 | Qnect](https://www.qnect.com/news-product-updates/release-notes-april-2024)

 Written by [Jeff Hausthor](https://www.qnect.com/news-product-updates/author/jeff-hausthor) | Jul 29, 2024 8:22:04 PM

- Preference pages missing choices for 5/8 in. angle profile thickness - They have now been added.
- Update Bolt Type Pulldowns and Functioning  
  Update Bolt type pulldown options to the following:  
  HH – Snug Tight  
  HH – Turn of Nut or Calibrated Wrench  
  HH – DTI  
  TC – Twist Off   
  “HH- Snug Tight” - Treat washers the same as current HH Option  
  “HH – Turn of Nut or Calibrated Wrench” - Treat washers the same as current case when using pretensioned Calibrated Wrench  
  “HH – DTI” - treat washers the same as current HH-DTI Option  
  “TC – Twist Off” - Treat washers the same as current TC Option

 

- Clashing connections in model from different sessions 
    - Resolved issue with Session 2 is run after Session 1 is finished and Session 1 connection is inserted into model.

 

- EPL - Add question and functioning for gaps and shims at End Plate to Beam 
    - For cases with mixed connection types on one beam, some that deserve gap and others that don’t, ie. DA’s at column one side, and End Plate other side with no gap required at Girder, or DA’s at column flange on one side, and DA’s at Girder opposite side (also no gap required), the gap should go on the side that causes the gap.  
      For example this case with DA’s at column one side when DA requires 2 gaps, and End Plate other side to Girder requires no gaps, so 2 one side, 0 other side, means 1 gap required, the gap should go on the side that causes the gap to occur, ie, the Column side, not the Girder side.

- web-environment: Fix text on Bop report

 

- qnect-cplus: Improve noconnect reason when profile+material grade combination in a check of nearby connections
  
    - This has been resolved - The issue appears when there is a nearby connection grouping, main is connecting to some other main or some other secondary is connecting to this secondary.  
      For example we have two groupings in a session
      
      BEAM1_TO_BEAM2  
      BEAM2_TO_COLUMN_FLANGE
      
      In our code we check if BEAM2_TO_COLUMN_FLANGE is too close to BEAM1_TO_BEAM2 connection.
      
      However when the other connection main part does not have a valid Profile + Material Grade combination, this connection grouping fails with  
      ”Failed to find material grade specification for profile. Please make sure that material grade specification exists for selected profile.”

[View full post](https://www.qnect.com/news-product-updates/release-notes-april-2024)

```json
{
  "@context" : "http://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Jeff Hausthor"
  },
  "dateModified" : "2025-05-27T09:33:28.739Z",
  "datePublished" : "2024-07-29T20:22:04Z",
  "headline" : "Release Notes: April 2024 | Qnect",
  "image" : {
    "@type" : "ImageObject",
    "height" : 630,
    "url" : "https://4536105.fs1.hubspotusercontent-na1.net/hubfs/4536105/cover-photo-2.jpg",
    "width" : 1200
  },
  "mainEntityOfPage" : "https://www.qnect.com/news-product-updates/release-notes-april-2024",
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "height" : 60,
      "url" : "/hs/hsstatic/content_shared_assets/static-1.4092/img/default-amp-logo.png",
      "width" : 60
    },
    "name" : "News & Product Updates"
  }
}
```